K-32327-NA

KOHLER Invigoration 11 kW steam generator

Published for steam rooms up to 317 ft³, subject to ceiling adjustment and every current installation requirement. This record uses the required service rating—not the lower electrical component draw.

Power
11 kW
Published maximum
317 ft³
Configuration
single
Required service
1 × 240 V / 60 A

System requirements shown by this planner

Generator assembly
1 × K-32327-NA
Dedicated circuits
1 × 240 V, 60 A, 50/60 Hz
Steam heads
1
Drain pans
1 × K-5559-NA (recommended)

Field provenance

  • Volume:317 cubic feet maximum volume rating
  • Electrical:One dedicated circuit required. Steam Generator: 240 V, 60 A, 50/60 Hz
  • Drain pan:K-5559 Small drain pan

Specification revision: 6-29-2026 20:53 - US-CA.

The maximum volume does not replace the ceiling rule

KOHLER recommends an 8-foot-or-lower ceiling and directs an upgrade to the next generator size for each foot above 8 feet. SteamDesignPro conservatively treats a started partial foot as an upward step and flags it for review because the current documents do not publish a fractional-foot policy.

Review the exact calculation