Current model record • source retrieved July 11, 2026

K-32325-NA

KOHLER Invigoration 7 kW steam generator

Published for steam rooms up to 112 ft³, subject to ceiling adjustment and every current installation requirement. This record uses the required service rating—not the lower electrical component draw.

Power
7 kW
Published maximum
112 ft³
Configuration
single
Required service
1 × 240 V / 50 A

System requirements shown by this planner

Generator assembly
1 × K-32325-NA
Dedicated circuits
1 × 240 V, 50 A, 50/60 Hz
Steam heads
1
Drain pans
1 × K-5559-NA (recommended)

Field provenance

  • Volume:112 cubic feet maximum volume rating
  • Electrical:One dedicated circuit required. Steam Generator: 240 V, 50 A, 50/60 Hz
  • Drain pan:K-5559 Small drain pan

Specification revision: 6-29-2026 20:53 - US-CA.

The maximum volume does not replace the ceiling rule

KOHLER recommends an 8-foot-or-lower ceiling and directs an upgrade to the next generator size for each foot above 8 feet. SteamDesignPro conservatively treats a started partial foot as an upward step and flags it for review because the current documents do not publish a fractional-foot policy.

Review the exact calculation